Siemens SINAMICS DCM List Manual page 161

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p2098[0...1]
Inverter connector-binector converter binector output / Con/bin outp inv
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
P-Group: Communications
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of connector input p2099[0] are influenced.
Using p2098[1], the signals of connector input p2099[1] are influenced.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
Refer to: r2094, r2095, p2099
p2098[0...1]
Inverter connector-binector converter binector output / Con/bin outp inv
TM150, TM15DI_DO,
Can be changed: U, T
TM31
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of connector input p2099[0] are influenced.
Using p2098[1], the signals of connector input p2099[1] are influenced.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
Refer to: r2094, r2095, p2099
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2460, 2481
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Access level: 3
Func. diagram: 2468
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents