2 Parameters
2.2 List of parameters
p50700

CUD analog input 0 type / CUD AI 0 type

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the type for analog input 0 (X177.25/26) on the CUD.
Value:
0:
1:
2:
Note:
AI: Analog Input
p50701[0...n]

CUD analog input 0 scaling / CUD AI 0 scal

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-1000.0 [%]
Description:
Sets the scaling for analog input 0 (X177.25/26) on the CUD.
The value indicates the percentage value for the mapping of an input voltage of 10 V or an input current of 20 mA at
the analog input.
Example:
p50701 = 90%
--> 10 V or 20 mA is scaled to 90%
--> 5 V or 10 mA is equivalent to 45%
p50702

CUD analog input 0 offset / CUD AI 0 offs

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the offset for analog input 0 (X177.25/26) on the CUD.
p50703

CUD analog input 0 signal processing / CUD AI 0 sig proc

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal processing mode for analog input 0 (X177.25/26) on the CUD.
Value:
0:
1:
2:
3:
500
Bipolar voltage input (-10 V ... +10 V)
Bipolar current input (-20 mA to +20 mA)
Unipolar current input monitored (+4 mA to +20 mA)
Signal not controlled
Signal absolute value generation
Signal inverted
Signal absolute value generation inverted
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
1000.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0