r51570

CCP order number / CCP Order No.

DC_CTRL
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the order number (MLFB) of the connected Converter Commutation Protector (CCP).
Value:
0:
250:
251:
252:
253:
254:
r51571

CCP rated supply voltage / CCP V_rated

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [V]
Description:
Displays the rated supply voltage according to the rating plate of the Converter Commutation Protector (CCP).
r51572

CCP rated current / CCP I_rated

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [A]
Description:
Displays the rated current according to the rating plate of the Converter Commutation Protector (CCP).
r51574.0...12

CO/BO: CCP state / CCP state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the state of the Converter Commutation Protector (CCP).
Bit field:
Bit
00
01
02
03
04
05
08
09
10
11
12
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No CCP connected
6RA7085-6FC00-0
6RA7091-6FC00-0
6RA7095-6FC00-0
6RA7090-6KC00-0
6RA7095-6KC00-0
Signal name
Voltage at U, V, W ok
Voltage at C - D greater than +100 V
Voltage at C - D less than -100 V
Turn-off capacitors have reached the
setpoint voltage
Turn-off in progress
Connection between parallel CCPs OK
Connector X165_2 (at DCM) is connected
with X165 (at CCP)
I2t value voltage limiting chopper 1 too high Yes
I2t value voltage limiting chopper 2 too high Yes
Memory for technical data for CCP OK
Chopper capacitors pre-charging completed Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
254
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [A]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6970
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 6970
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: 6970
Unit selection: -
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 6970
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
FP
6970
6970
6970
6970
6970
6970
6970
6970
6970
6970
6970