r50069[0...31]

Power unit serial number / PU ser no.

DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the serial number of the power unit.
Note:
The individual digits of the number are displayed in ASCII code in the indices.
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
r50070[0...31]

Power unit order number / PU Order No.

DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the order number (MLFB) of the power unit.
Note:
The individual digits of the number are displayed in ASCII code in the indices.
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
r50071

Device rated line-side voltage armature / Device Ua_rated

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [Vrms]
Description:
Displays the device rated line-side voltage for the armature as indicated on the device's nameplate.
r50072[0...1]

Device rated direct current armature / Device Ia rated

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [A]
Description:
Displays the device rated direct current (armature).
Index:
[0] = Device rated direct current armature
[1] = Reduced rated direct current armature
Note:
Re index 0:
Device rated direct current (armature) as indicated on the device's nameplate.
Re index 1:
Actual device rated direct current (armature) according to the setting in parameter p50076[0] or p50067.
Also see the note for parameter p50076[0].
388
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [Vrms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [A]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
Access level: 1
Func. diagram: 6800, 6825,
6830, 6840, 6850, 6851, 6855,
6910, 6960, 6965, 8038, 8040,
8042
Unit selection: -
Expert list: 1
Factory setting
- [A]