Cbe2X Remote Controller Number / Cbe2X Rem Ctrl Num; Cbe20 Firmware Selection / Cbe20 Fw Sel; Sinamics Link Address / Sinamics Link Add - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
For p8811 = 16, the following applies:
Min/max/factory setting: 500/500/500 µs
For p8811 = 64, the following applies:
Min/max/factory setting: 1000/2000/2000 µs
p8829

CBE2x remote controller number / CBE2x rem ctrl num

CU_DC (PROFINET
Can be changed: C1(1)
CBE20), CU_DC_R
Data type: Integer16
(PROFINET CBE20),
P-Group: Communications
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
1
Description:
Sets the number of remote controllers expected for PROFINET CBE20/CBE25.
The "Shared Device" functionality is activated with a value = 2.
The drive is being accessed by two PROFINET controllers simultaneously:
- automation controller (SIMOTION or SIMATIC A-CPU).
- safety controller (SIMATIC F-CPU).
Value:
1:
2:
Notice:
The F CPU may only use PROFIsafe telegrams.
The A CPU must be connected to enable the F CPU to gain access.
Set the value = 1 to commission the F CPU individually.
Note:
A change only becomes effective after a POWER ON.
p8835

CBE20 firmware selection / CBE20 FW sel

CU_DC (PROFINET
Can be changed: C1(1)
CBE20), CU_DC_R
Data type: Integer16
(PROFINET CBE20),
P-Group: Communications
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
1
Description:
Selects the firmware version for the CBE20.
Value:
1:
3:
4:
99:
Note:
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
CBE20: Communication Board Ethernet 20
p8836

SINAMICS Link address / SINAMICS Link add

CU_DC (PROFINET
Can be changed: C1(1)
CBE20), CU_DC_R
Data type: Unsigned16
(PROFINET CBE20),
P-Group: Communications
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Selects the node address for the SINAMICS Link on the Communication Board Ethernet 20 (CBE20).
p8836 = 0: SINAMICS Link de-activated
p8836 = 1 ... 64: SINAMICS Link node address
Dependency:
Refer to: p8835
Note:
SINAMICS Link requires that the appropriate CBE20 firmware version is selected (p8835 = 3).
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
316
Automation or Safety
Automation and Safety
PROFINET Device
SINAMICS Link
EtherNet/IP
Customer-specific from the OEM directory
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
64
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 2198
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 2198
Unit selection: -
Expert list: 1
Factory setting
0