Activate/De-Activate Drive Object / Do Act/Deact - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r0103
Application-specific view / Appl_spec view
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Closed-loop control
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Displays the application-specific view of the individual drive object.
Dependency:
Refer to: p0107, r0107
p0105

Activate/de-activate drive object / DO act/deact

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate a drive object.
Value:
0:
1:
Dependency:
Refer to: r0106
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
p0105
Activate/de-activate drive object / DO act/deact
DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Closed-loop control
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate a drive object.
Value:
0:
1:
2:
Recommendation:
After inserting all of the components of a drive object, before activating, first wait for Alarm A01316.
Dependency:
Refer to: r0106
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
p0105
Activate/de-activate drive object / DO act/deact
TM150, TM15DI_DO
Can be changed: T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate a drive object.
Value:
0:
1:
2:
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
De-activate drive object
Activate drive object
De-activate drive object
Activate drive object
Drive object de-activate and not present
De-activate drive object
Activate drive object
Drive object de-activate and not present
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
47