p2103[0...n]

BI: 1. Acknowledge faults / 1. Acknowledge

DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Messages
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the first signal source to acknowledge faults.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2104

BI: 2. Acknowledge faults / 2. Acknowledge

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Binary
CU_DC_S, TM150,
P-Group: Messages
TM15DI_DO, TM31
Not for motor type: -
Min
-
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2104[0...n]
BI: 2. Acknowledge faults / 2. Acknowledge
DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Messages
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2105

BI: 3. Acknowledge faults / 3. Acknowledge

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Binary
CU_DC_S, TM150,
P-Group: Messages
TM15DI_DO, TM31
Not for motor type: -
Min
-
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2105[0...n]
BI: 3. Acknowledge faults / 3. Acknowledge
DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Messages
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
0