2 Parameters
2.2 List of parameters
p50716

BI: CUD analog input 1 signal source for enable / CUD AI 1 ena sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling analog input 1 (X177.27/28) on the CUD.
Note:
1 signal:
Analog input is enabled
0 signal:
Analog input is disabled (value = 0%)
p50717

CUD analog input 1 simulation setpoint / CUD AI 1 sim setp

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-130.0 [%]
Description:
Sets the setpoint for the simulation of analog input 1 (X177.27/28) on the CUD.
Dependency:
Refer to: p50719
Note:
Simulation is selected using p50719 = 1.
p50719

CUD analog input 1 simulation selection / CUD AI 1 sim sel

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to select the simulation of analog input 1 (X177.27/28) on the CUD.
Value:
0:
1:
Dependency:
Refer to: p50717
Note:
The setpoint for the simulation is set in p50717.
p50721[0...n]

CUD analog input 2 scaling / CUD AI 2 scal

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-1000.0 [%]
Description:
Sets the scaling for analog input 2 (X177.29/30) on the CUD.
The value indicates the percentage value for the mapping of an input voltage of 10 V at the analog input.
Example:
p50721 = 90%
--> 10 V is scaled to 90 %
--> 5 V corresponds to 45 %
Note:
AI: Analog Input
504
Simulation deactivated
Simulation activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
130.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
1000.0 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1