p50614[0...4]
CI: Field current setpoint limiting sig source for var lower limit / If_lim l lim sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for generating the lower limit of the field current setpoint (CO: r52274).
Dependency:
Refer to: p50103, r52274
p50615[0...3]

CI: EMF controller setpoint signal source / EMF ctr set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setpoints on the EMF controller.
Index:
[0] = Setpoint 0
[1] = Setpoint 1
[2] = Setpoint 2
[3] = Setpoint 3
Dependency:
Refer to: r52288
Note:
The overall setpoint is available via connector output r52288 for further interconnection.
p50616
CI: EMF controller actual value signal source / EMF ctr act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the actual value on the EMF controller.
Dependency:
Refer to: r52285
Note:
The actual value is available via connector output r52285 for further interconnection.
p50618
CI: Field gating unit signal source for field direction / Field g unit dir
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the field direction on the field gating unit.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6905
Unit selection: -
Expert list: 1
Factory setting
[0...3] 1
[4] 0
Access level: 3
Func. diagram: 6900
Unit selection: -
Expert list: 1
Factory setting
[0] 52289[0]
[1] 0
[2] 0
[3] 0
Access level: 3
Func. diagram: 6900
Unit selection: -
Expert list: 1
Factory setting
52286[0]
Access level: 3
Func. diagram: 6915
Unit selection: -
Expert list: 1
Factory setting
52268[0]