p50473[0...n]

Motorized potentiometer save output value / MotP save outp val

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets how the output value is saved on the motorized potentiometer.
Value:
0:
1:
Dependency:
Refer to: p50467, r52240
Note:
If p50473 = 0:
The output value (CI: r52240) is not saved. The starting value specified in p50467 is applied after ON.
If p50473 = 1:
The output value (CI: r52240) is saved to non-volatile memory after OFF. The saved value is applied after ON.
p50480[0...n]

Oscillation setpoint 1 / Oscillation set 1

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.0 [%]
Description:
Sets setpoint 1 for the square-wave generator.
Dependency:
Refer to: p50481, p50482, p50483
Note:
This setpoint is applied for the time set in p50481.
p50481[0...n]

Oscillation setpoint 1 time / Oscill set 1 t

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.1 [s]
Description:
Sets the time during which setpoint 1 should be applied for the square-wave generator.
Dependency:
Refer to: p50480, p50482, p50483
p50482[0...n]

Oscillation setpoint 2 / Oscillation set 2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.0 [%]
Description:
Sets setpoint 2 for the square-wave generator.
Dependency:
Refer to: p50480, p50481, p50483
Note:
This setpoint is applied for the time set in p50483.
464
Save de-activated
Save activated
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
300.0 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.0 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
0.5 [%]
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
0.1 [s]
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
-0.4 [%]