p51651[0...n]

Speed controller start pulse positive setpoint / Start pul pos set

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-100.00 [%]
Description:
Sets the setpoint for the positive start pulse on the speed controller.
Recommendation:
The value can also be used as an integrator setting value for the speed controller.
p51652[0...n]

Speed controller start pulse negative factor / Start pul neg fact

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the factor for the start pulse when the setpoint is negative.
p51653[0...n]

Speed controller start pulse negative setpoint / Start pul neg set

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-100.00 [%]
Description:
Sets the setpoint for the negative start pulse on the speed controller.
p51655
CI: Speed controller start pulse positive signal source / Start p pos sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setpoint of the positive start pulse on the speed controller.
p51656
CI: Speed controller start pulse negative signal source / Start p neg sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setpoint of the negative start pulse on the speed controller.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6800
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 6800
Unit selection: -
Expert list: 1
Factory setting
50.00 [%]
Access level: 2
Func. diagram: 6800
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 6800
Unit selection: -
Expert list: 1
Factory setting
52451[0]
Access level: 2
Func. diagram: 6800
Unit selection: -
Expert list: 1
Factory setting
52452[0]