Lead/Lag Element Rate Time / Lead/Lag T_Rate; Lead/Lag Element Filter Time / Lead/Lag T_Filter; Speed Controller Droop Effective / N_Ctr Droop Eff; Speed Controller Integral Time Effective / N_Ctr Tn Eff - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50208[0...n]

Lead/lag element rate time / Lead/lag t_rate

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
2 [ms]
Description:
Sets the rate time for the lead/lag element.
Dependency:
Refer to: p50207, p50209, r52156
p50209[0...n]

Lead/lag element filter time / Lead/lag t_filter

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
2 [ms]
Description:
Sets the filter time for the lead/lag element.
Dependency:
Refer to: p50207, p50208, r52156
r50217

Speed controller droop effective / n_ctr droop eff

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the effective droop on the speed controller.
Notice:
The effective droop is displayed as absolute factor without any dimensions and it is especially important to note that
it is not a percentage.
Example:
r50217 = 0.05 --> corresponds to an effective droop of 5 %.
r50218

Speed controller integral time effective / n_ctr Tn eff

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [s]
Description:
Displays the effective integral time (Tn) on the speed controller.
r50219
CO: Speed controller P-gain effective / n_ctr Kp eff
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the effective P gain (Kp) on the speed controller.
422
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [s]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
2 [ms]
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
2 [ms]
Access level: 1
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
- [s]
Access level: 1
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
-