Ci: Technology Controller Pre-Control Signal / Tec_Ctr Prectr_Sig; Co: Technology Controller Maximum Limiting / Tec_Ctrl Max_Lim; Co: Technology Controller Minimum Limiting / Tec_Ctrl Min_Lim; Technology Controller Ramp-Up/Ramp-Down Time / Tec_Ctr T_Ru/Rd - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p2289[0...n]

CI: Technology controller pre-control signal / Tec_ctr prectr_sig

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: Unsigned32 / FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Sets the signal source for the pre-control signal of the technology controller.
p2291

CO: Technology controller maximum limiting / Tec_ctrl max_lim

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-200.00 [%]
Description:
Sets the maximum limit of the technology controller.
Dependency:
Refer to: p2292
Caution:
The maximum limit must always be greater than the minimum limit (p2291 > p2292).
p2292

CO: Technology controller minimum limiting / Tec_ctrl min_lim

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-200.00 [%]
Description:
Sets the minimum limit of the technology controller.
Dependency:
Refer to: p2291
Caution:
The maximum limit must always be greater than the minimum limit (p2291 > p2292).
p2293

Technology controller ramp-up/ramp-down time / Tec_ctr t_RU/RD

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
0.00 [s]
Description:
Sets the ramping time for the output signal of the technology controller.
Dependency:
Refer to: p2291, p2292
Note:
The time refers to the set maximum and minimum limits (p2291, p2292).
188
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
100.00 [s]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
1.00 [s]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading