2 Parameters
2.2 List of parameters
Bit 01 = 1 (enable signal missing), if:
- the signal source in p0844 or p0845 is a 0 signal.
Bit 03 = 1 (enable signal missing), if:
- the signal source in p0852 is a 0 signal.
Bit 16 = 1 (enable signal missing), if:
- there is an OFF1 fault response. The system is only enabled if the fault is removed and was acknowledged and the
"switching on inhibited" withdrawn with OFF1 = 0.
Bit 17 = 1 (enable signal missing), if:
- the commissioning mode is selected (p0009 > 0 or p0010 > 0) or there is an OFF2 fault response or the OFF1
signal source (p0840) is changed.
r0049[0...3]

Encoder data set effective / EDS effective

Can be changed: -
DC_CTRL,
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the effective Encoder Data Sets (EDS).
Index:
[0] = Reserved
[1] = Encoder 1 Encoder Data Set EDS effective
[2] = Encoder 2 Encoder Data Set EDS effective
[3] = -
Dependency:
Refer to: p0187, p0188
Note:
Value 99 means the following: No encoder assigned (not configured).
r0050.0

CO/BO: Command Data Set CDS effective / CDS effective

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the effective Command Data Set (CDS).
Bit field:
Bit
00
Dependency:
Refer to: p0810, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0051.0...1

CO/BO: Drive Data Set DDS effective / DDS effective

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the effective Drive Data Set (DDS).
Bit field:
Bit
00
01
Dependency:
Refer to: p0820, p0821, r0837
42
Signal name
CDS eff bit 0
Signal name
DDS eff bit 0
DDS eff bit 1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8560
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF