Sign In
Upload
Manuals
Brands
Siemens Manuals
Control Unit
Add 7 AddFEM
Siemens Add 7 AddFEM Manuals
Manuals and User Guides for Siemens Add 7 AddFEM. We have
1
Siemens Add 7 AddFEM manual available for free PDF download: Manual
Siemens
Add 7 AddFEM
Manual
Siemens Add 7 AddFEM Manual (148 pages)
Front End Module
Brand:
Siemens
| Category:
Control Unit
| Size: 1.02 MB
Table of Contents
Table of Contents
8
1 Area of Application
12
Categorization and Features
13
Applications of the Variants 6DL3100-8AC
15
2 Design
19
Structure of the Addfem
19
Figure 2-1 Addfem with and Without Cover
19
Operating and Display Elements
20
Table 2-1 Explanation of the Error/Status Leds
23
Connection Elements
24
Figure 2-3 Connection Elements
24
Figure 2-4 Module Supply 24 V DC
25
Figure 2-5 Front Connector
26
3 Mode of Operation
28
Functional Features
29
Operating States
29
General Features
31
Operating Principle of the 2-Channel Speed Detection with Sense of Rotation Recognition
32
Operating Modes
34
Redundancy Functions with Addfem
37
Redundancy of PROFIBUS DP Connection
40
Monitoring and Changeover by Means of Signs of Life
41
Figure 3-7 Sign of Life from Host to Addfem
41
Table 3-1 Monitoring Criteria
41
Figure 3-8 Changing the Sign of Life
42
Self-Learning Sign of Life Cycle Time
43
Status Information from Addfem to the AP
43
Redundant Addfems
44
Figure 3-9 Operating States from POWER-ON to RUN
44
Figure 3-10 Signals for Controlling the Redundancy Logic
46
Interconnection of Redundant Inputs and Outputs
47
Figure 3-11 Possible Redundancy Configurations
48
Figure 3-12 Applicable Diodes
48
Preprocessing Functions with Addfem (Applies Only for 6DL3100-8AB)
49
4 Technical Data
53
Figure 4-1 Characteristic Curve Image for Digital Inputs
55
Figure 4-2 Characteristic Curve Image for Counting Pulse Inputs
57
Safety, Environmental Conditions and EMC
65
PROFIBUS DP Telegram Structure
69
Parameterization Telegram
69
Input Telegram
70
Output Telegram
74
Coding of the Analog Values and Measured Value Ranges
76
5 Commissioning / Operation / Maintenance
82
Mounting the Addfem
83
Figure 5-1 Dimensioned Drawing for DIN Rail Mounting
84
Figure 5-2 Dimensioned Drawing for Screw Mounting
85
Figure 5-3 Module Supply 24 V DC
86
Setting the PROFIBUS-DP Address
90
Setting the PROFIBUS DP Address for Bus a Via Key-Operated and Slide Switches
90
Figure 5-4 Operating Elements of the Addfem
90
Table 5-1 Setting the PROFIBUS-DP Address for Bus a Via Key-Operated and
91
Setting the PROFIBUS-DP Address for Bus B Via Key-Operated and Slide Switches
93
Table 5-2 Setting the PROFIBUS-DP Address for Bus B Via Key-Operated and
94
Table 5-3 Checking the Setting of the PROFIBUS-DP Address
96
Resetting the Addfem
97
Table 5-4 Resetting the Addfem
97
Setting the PROFIBUS-DP Address Via the SIMATIC-Manager
98
Figure 5-5 Assignment of the PROFIBUS-DP Address Via the SIMATIC-Manager
98
Operating and Display Elements
99
Table 5-5 Explanation of the Error/Status Leds
102
Configuring the Addfem
107
Figure 5-7 Configuring the Addfem by Means of the COM PROFIBUS
107
Figure 5-8 Configuring the Operating Mode
108
Figure 5-9 Configuring the Analog Inputs
109
Figure 5-10 Configuring the Analog Outputs
110
Figure 5-11 Configuring Counter 1
111
Figure 5-12 Configuring the Filtering of the Analog Inputs
112
Figure 5-13 Configuring the Delayed Disconnection
113
Figure 5-14 Configuring the Front-End Functions
114
Configuring the Driver Blocks
115
Figure 5-15 Installation Sequence of the Driver Function Blocks
116
Figure 5-16 Overview of the Driver Blocks with FEF Functionality
118
Configuration of the Addfem Driver Block with Continuous Function Chart
119
Figure 5-17 Representation of Addfem Driver Blocks in CFC
119
Figure 5-18 Configuration at Single-Channel Use
121
Figure 5-19 Redundant as
122
Figure 5-20 Addfem Redundant
123
AS Redundant and Addfem Redundant (Operating Mode 3)
124
Figure 5-21 as Redundant and Addfem Redundant
124
Processing Times for Driver Function Blocks
125
Required Memory Space
125
Detailed Description of the Driver Function Blocks
126
FEM_AO - Analog Output
133
FEM_DI - Binary Input
136
FEM_DO - Binary Input
141
Fault Elimination
144
Failure and Exchange of Redundant Addfems During Operation
144
Front Connector Configuration
146
Advertisement
Advertisement
Related Products
Siemens SIRIUS ACT 3SU1
Siemens A80485-1
Siemens SENTRON ATC6500
Siemens MOBY I ASM 421
Siemens SITRANS AW 7MP3112 Series
Siemens AGM60.4A9
Siemens SIDOOR ATD4 W Series
Siemens SIRIUS ACT 3SU18 N Series
Siemens SIRIUS ACT 3SU140 E N Series
Siemens SIRIUS ACT 3SU14
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL