Image Adjustments
Scanning
Before doing the following scanner adjustments check the printing registration/side-to-side adjustment and
the blank margin adjustment. Use a C4 Test Chart to perform the following adjustments.
Scanner sub-scan magnification
1. Place the test chart on the exposure glass and make a copy.
2. Check the magnification ratio. Use SP4008 (Sub Scan Mag) to adjust if necessary. Standard: ±1.0%.
Image Adjustments
4
507