Ricoh V-C3 D081 Field Service Manual page 839

Table of Contents

Advertisement

Sets the absolute humidity to be compared with the relative humidity from the last time the K
drum motor stopped. The reading is updated every 10 minutes.
[0 to 99/ 6 1 g/m
5 Max Times
Sets the maximum number of times for these SP codes to execute while the machine remains
in standby mode.
[0 to 99/ 10/ 1 times]
3556
Latest Print Date Time
These SP settings display the date of the most recent print job.
1 Year
[1 to 12/1/1 year]
2 Month
[1 to 31/1/1 month]
3 Day
[1 to 23/1/1 day]
4 Hour
[1 to 23/1/1 hour]
5 Min.
[1 to 59/1/1 min.]
3561
Dev gamma:Disp/Set
Displays the value of development gamma, an indicator of development capacity. In
order for the machine to determine the development potential to obtain the target
coverage. During processing control the graduated patterns are created first on the drums
and then on the ITB. The potential sensors read the development potential, and the ID
sensors read the amount of coverage on the ITB.
Plotting the development potential on the X axis against coverage on the Y-axis results in
the development gamma curve. For more, see "Process Control" in Section 6.
1-4 Actual Val:K,M,C,Y
5-8 Target Val:K,M,C,Y
9-12 Initial Val:K,M,C,Y
13 Environ Corr:Bk
14 Environ Corr:Col
15-18 Time Lapse Corr:K,M,C,Y
3
]
Group 3000
4
261

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082

Table of Contents