Ricoh V-C3 D081 Field Service Manual page 717

Table of Contents

Advertisement

Z-Fold Timing Sensor Adjustment Error 2 Japan Only
The output voltage light emitted from the sensor changed, but the return input was not
sufficient to attain V0.
SC785
B
• Sensor, mirror dirty from paper dust, other particles
• Harness loose, broken, defective
• Mirror out of position
Z-Fold Memory Error Japan Only
Several attempts to write to the Z-fold memory failed.
SC786
B
• Turn the machine power off/on
• EEPROM on Z-Folder main board defective
Proof Tray Exit Motor Error
The motor drive PCB detected an error at the motor due to overload, overheating.
SC789
B
Paper cannot exit at proof tray.
• Motor, motor drive board defective
Important: The S792-** SC Codes apply to the Ring Binder D392.
Junction gate error
Detected at HP after the time prescribed to leave the HP had elapsed (more than
36 pulses) (1 detection, jam, twice detected, SC error)
-or-
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more
than 22 pulses) (1 detection, jam, twice detected, SC error)
SC792-1
B
• Path JG motor (M201) defective
• Motor connector loose, broken, defective
• Motor overload
• Path JG sensor (S203) connector loose, broken, defective
• Sensor (S203) defective