Chg Wire Cleaning Time
These SPs display the duration of wire cleaning after the wires were cleaned using SP codes
001 to 005 above.
6 Result: Forward
7 Result: Back
2223
OPC Rev After Idle Time
These SP codes allow you to set up how long the OPC will idle at the start of a print job after it
has remained inactive.
1 Execution Setting
2 Execution Timing
3 Exec Threshold:Rel Humidity
4 Exec Threshold:Idle Time
5 Exec Threshold:OPC Usage
[0 to 45/ 0 / 0.1 sec.]
Switches this SP code on/off. Default: Off (0)
This SP must be set on for the other values (2 to 5 below)
to take effect.
Sets the amount of time for the OPC drum to idle before
the start of the job.
[0 to 360/ */1 sec.]
* Default setting:
D014: 75 sec.
D015: 60 sec.
Sets the threshold of relative humidity to trigger idling of
the OPCu.
[0 to 99/ 65/ 1 %rH]
Sets the length of time for the OPC to idle, once the idle
time has been triggered by the rH threshold.
[0 to 6000/ 360/ 10 min.]
Sets the threshold value to trigger OPC idling, depending
of the number of pages printing.
[0 to 400 000 / 60 000/ 10 000 sheets]
Group 2000
4
207