Punch defective
One or more of the following occurred:
• Punch unit not detected at initialization.
• No motor rotation detected at HP at 30 ms after the DC motor turned on
• No encoder pulse detected at HP at 5 ms after the DC motor turned on
• Not detected at HP at 400 ms after the DC motor turned on
SC792-4
B
• Punch motor (M304) connector loose, broken, defective
• Motor overload
• Motor defective
• Punch HP sensor (S302) connector loose, broken, defective, or sensor
• Punch encoder sensor (S303) connector loose, broken, defective, or sensor
Paddle roller HP error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more
than 400 ms) (1st detection, jam, 2nd detection, SC error)
-or-
Detected at HP after the time prescribed to leave the HP had elapsed (more than
400 ms) (1st detection, jam, 2nd detection, SC error)
SC792-5
B
• Paddle roller lift motor (M603) connector loose, broken, defective
• Motor overload
• Motor defective
• Paddle roller HP sensor (S602) connector loose, broken, defective
• Sensor defective
defective
defective
Service Call Tables