Ricoh V-C3 D081 Field Service Manual page 827

Table of Contents

Advertisement

Toner Calibration Time: Display
Displays for confirmation the length of time the sub hopper clutch remained on to send toner
to the sub hopper after a new toner cartridge was installed.
1 Sub Hopper CL:K
2 Sub Hopper CL:M
3 Sub Hopper CL:C
4 Sub Hopper CL:Y
5 Toner Pump CL:K
6 Toner Pump CL:M
7 Toner Pump CL:C
8 Toner Pump CL:Y
3301
Tnr Supply
Select toner supply method
1 K
2 M
3 C
4 Y
3302
Tnr Supply
Sets the toner supply rate for fixed toner supply mode. The rate is set by adjusting the on time
of the toner supply clutch. This setting is used only if SP3301 is set to "0".
1 Supply Rate:K
2 Supply Rate:M
3 Supply Rate:C
4 Supply Rate:Y
[0 to 99 999 999/1 ms]
Use these SPs to display the accumulated drive time for each
powder pump clutch before installing a new one.
[0 to 99 999 999/1 ms]
[0 to 1/1]
0: Fixed toner supply
1: PID Toner Supply
[0 to 100/ 1%]
Group 3000
4
249

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082