4. Appendix: Service Program Mode Tables
Set Target Amount for Process Control
This SP sets the value for the maximum coverage to be achieved by the process control self-
check. Process control then analyzes the readings of the 4-grade pattern, calculates the
potentials required for development gamma and Vk (starting voltage), and then determines
the drum charge levels, development biases, and LD power levels necessary to achieve the
target coverage.
Note
• This SP can be used to darken printed images.
After this SP is changed, process control must be executed manually with SP3820.
1 Max Tnr Amt:K
4
2 Max Tnr Amt:M
3 Max Tnr Amt:C
4 Max Tnr Amt:Y
3540
Image Quality Adjust: Interval
Adjusts the interval between image quality adjustments.
1 During Job
2 During Standby
3551
Set Procon:Job End
This SP sets timing of the process control self-check for job end. The process control self-
check never interrupts a job to execute, even if it is time for the next self-check.
1 B/W Mode
This SP sets the page interval for execution of process control at job end for monochrome
printing.
[0 to 5000/250/1]
2 Color Mode
258
[0 to 1/ 0.001 mg/cm
Sets the page interval for image quality adjustment.
[0 to 100/30/1 Page]
Sets the time interval for image quality adjustment while the machine is
in standby mode.
[0 to 100/10/1 Min.]