Ricoh V-C3 D081 Field Service Manual page 337

Table of Contents

Advertisement

6. Disconnect the spring from the O-ring. Keep the spring because you will need it to attach the new
wire.
7. At the rear, use the pincettes to pull the spring [A] of the other wire gently toward the rear and lift it
off its peg [B].
8. At the front, remove the other end of the corona wire from its peg [C].
PCU
4
335

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082

Table of Contents