9
16. Touch [Exit] twice, open the front door and confirm that each developer bottle is completely empty.
• Each developer bottle must be completely empty.
• Even if SP3815 returned a "1" for each bottle to indicate successful completion of the operation,
there may be some toner remaining in a bottle.
• It is very important that you check each bottle visually for remaining developer.
17. Shine a flashlight on each bottle and confirm that each bottle is empty.
• If you see any remaining toner, gently tap the neck of the bottle to loosen the toner then execute
SP3814 again to drain all the developer.
18. After all the developer has drained from each bottle, switch the machine off.
What It Means
Developer filled before doing SP3814-1
Failed
Main Machine D081/D082
2
73