SC413
D
ID sensor error: Development γ Y
Development gamma for black, magenta, cyan, or yellow is not within range (0.3
to 6.0). Process control halts when this SC is issued.
• Toner density abnormal. Refer to the image troubleshooting section in Section
4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59,
61).
• LD sensor harness loose, broken, defective
• Potential sensor defective
• LD unit not firing
• ITB separation for CMY abnormal
• Transfer power pack defective
SC414
D
ID sensor error: Development start voltage K
SC415
D
ID sensor error: Development start voltage M
SC416
D
ID sensor error: Development start voltage C
SC417
D
ID sensor error: Development start voltage Y
The development start voltage in the development of the black, magenta, cyan, or
yellow PCU is not within the correct range (±150V)
• Toner density abnormal. Refer to the image troubleshooting section in Section
4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59,
61).
• Potential sensor defective
• LD unit not firing
• ITB separation for CMY abnormal
• Transfer power pack defective