Ricoh V-C3 D081 Field Service Manual page 699

Table of Contents

Advertisement

Upper Transport Motor Error (Proof Tray): B830
No encoder pulse signal is detected for the upper transport motor within 600 ms. The
1st failure causes this SC code.
• Upper transport motor disconnected, defective
SC731
B
• Finisher connection to upper transport motor loose, defective
• Upper transport motor blocked by an obstruction
• Upper transport motor defective
• Finisher main board defective
Shift Tray Exit Motor: 3K Finisher B830
The shift tray exit motor is not operating.
• Motor harness loose, broken, defective
SC732
B
• Motor is blocked by an obstruction
• Motor defective
• Finisher main control board defective
Stapler Exit Motor: B830
The stapler exit motor is not operating.
• Motor harness loose, broken, defective
SC733
B
• Motor is blocked by an obstruction
• Motor defective
• Finisher main control board defective
Upper Tray Junction Gate Motor: 3K Finisher B830
The upper tray junction gate HP sensor did not detect the gate at the home position
within 200 ms after two attempts.
-or-
SC734
B
The HP sensor twice detected the gate at the home position for more than 200 ms
after it was supposed to open.
• Junction gate did not arrive at the home position within the specified time
• Junction gate did not leave the home position within the specified time
Service Call Tables
3
121

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082