3. Appendix: Service Call Conditions
SC792-10
B
3
SC792-11
B
SC792-12
B
144
Binder unit runout error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more
than 400 ms) (1st detection, jam, 2nd detection, SC error)
-or-
Detected at HP after the time prescribed to leave the HP had elapsed (more than
400 ms) (1st detection, jam, 2nd detection, SC error)
• Runout press roller motor (M610) connector loose, broken, defective
• Motor defective
• Motor overload
• Runout roller HP sensor (S614) connector loose, broken, defective
• Sensor defective
Clamp thickness error
50-sheet detection sensor (S606) went OFF during pre-bind jogging when a 100-
sheet thickness was detected. (1st detection jam, 2nd detection SC error)
-or-
50-sheet detection sensor went OFF at initialization when the clamp moved to the
open position.
• 50-sheet detection sensor (S606) connector loose, broken, defective
• Sensor defective
Alignment pin error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more
than 400 ms) (1st detection, jam, 2nd detection, SC error)
-or-
Detected at HP after the time prescribed to leave the HP had elapsed (more than
400 ms) (1st detection, jam, 2nd detection, SC error)
• Alignment pin motor (M602) connector loose, broken, defective
• Motor overload
• Motor defective
• Alignment pin HP sensor (S604) connector loose, broken, defective
• Sensor defective