4. Replacement and Adjustments
1. Re-position the return position sensor bracket [A] ( x 1).
2. For A4 set the screw in the left hole [B].
-or-
For LT set the screw in the right hole [C].
3. Input the new paper size into SP5959 001.
Reinstallation
• Do the scanner and registration adjustments (

Side-to-Side Registration Correction

4
1. Open the tandem tray.
2. Remove front cover [A] of the right tray ( x2).
3. Loosen screw [B].
4. Remove the screw from round hole [C] and move it to oval hole [D].
5. Look at the scale [E] through the cut-out.
6. Shift the plate forward or back, check the position on the scale, and then tighten both screws to set
the plate at the new position.