PCU
4
6. At the front, thread the corona wire across the surface of pad [A] and pad [B].
7. At the rear, use pincettes to gently pull the end of the spring and hook it over the peg.
• The wire is fragile. Do not use too much force when pulling.
8. At the rear, hook a spring [A] onto the O-ring of the second corona wire.
9. Hook the other end of the corona wire (without the spring) onto its front peg [B].
339