4. Appendix: Service Program Mode Tables
1 Voffset_Reg
2 Voffset_Dif
3121
Adjusted Vsg DFU
This SP displays the 1) results of the most recent Vsg adjustment.
1 Vsg_Reg:Col
2 Vsg_Dif:Col
4
3131
Ifsg After Vsg
Displays as a PWM value (pulse width modulation) the level of the ID sensor LED after Vsg
has been adjusted. Normal Vsg readings of the ITB bare surface reflectivity should be in the
range 4.0 ±0.2V.
1 lfsg: Ctr
3 lfsg: Ini
3141
ID Sn:Vmin
Displays the minimum values read from the graduated patterns read by the ID sensor during
process control.
3194
ID Coeff Display
Displays the most recent and averaged readings of the sensitivity correction coefficients (K2
and K5).
1 K2:Last
2 K5:Last
5 K2:Ave
6 K5:Ave
3251
Tnr Supply Time
248
[0 to 5/0.01 V]
[0 to 5/0.01 V]
[0 to 4096/1]
[0 to 5/0.0001]