2. Installation
2
15. On the LCT, raise the paper exit cover [A].
16. Pull the paper tray [B] about halfway out of the unit.
17. Remove the left corner cover (upper) [C] ( x2).
18. Remove the left corner cover (middle) [D] ( x2).
19. Remove the left corner cover (lower) [E] ( x2).
20. Push the paper tray [B] into the LCIT.
• The paper tray [B] must be pushed in now. If the paper tray remains out, the LCIT is unstable and
difficult to move.
138