Ricoh V-C3 D081 Field Service Manual page 779

Table of Contents

Advertisement

45 C Area 4
46 C Area 5
47 C Area 6
48 C Area 7
49 C Area 8
50 C Area 9
51 C Area 10
52 C Area 11
61 Y Area 0
62 Y Area 1
63 Y Area 2
64 Y Area 3
65 Y Area 4
66 Y Area 5
67 Y Area 6
68 Y Area 7
69 Y Area 8
70 Y Area 9
71 Y Area 10
72 Y Area 11
220
Set AC (Fixed) Charge
2
These SPs set the AC bias for the standard speed mode and low speed mode, but take effect only
when SP3501 001 is set to "1" (Fixed). The default ac bias for each color is 2.2 kV (220) The
ac bias is normally adjusted by process control self-check, but when automatic process control
is switched off (by setting SP3501 001 to "1"), these values are used for the charge potential.
1 Wire Current:K
Group 2000
4