Ricoh V-C3 D081 Field Service Manual page 899

Table of Contents

Advertisement

Sets the count level for the PM alarm.
[0 to 9999/1]
0: Alarm disabled
The PM alarm goes off when the print count reaches this value multiplied by 1,000.
5504
Jam Alarm Japan Only
5505
Error Alarm Japan Only
5507
Supply Alarm Japan Only
5508
CC Call Japan Only
1 Jam Remains
2 Continuous Jams
3 Continuous Door Open
4 Low Call Mode
Enables/disables the new call specifications designed to reduce the number of calls.
[0 to 1/1]
0: Normal mode
1: Reduced mode
11 Jam Detection: Time Length
Sets the length of time to determine the length of an unattended paper jam.
[03 to 30/1]
This setting is enabled only when SP5508-004 is enabled (set to 1).
12 Jam Detection Continuous Count
Sets the number of continuous paper jams required to initiate a call.
[02 to 10/1]
This setting is enabled only when SP5508-004 is enabled (set to 1).
13 Door Open: Time Length
Enables/disables initiating a call.
[0 to 1/1]
0: Disable
1: Enable
Group 5000
4
321

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082

Table of Contents