Ricoh V-C3 D081 Field Service Manual page 947

Table of Contents

Advertisement

Bluetooth
5851
Sets the operation mode for the Bluetooth Unit. Press either key.
[0: Public] / [1: Private]
Stamp Data Download
Touch [EXECUTE] to download the fixed stamp data from the machine ROM onto the hard
disk. Then these stamps can be used by the system. If this is not done, the user will not have
5853
access to the fixed stamps ("Confidential", "Secret", etc.).
You must always execute this SP after replacing the HDD or after formatting the HDD. Always
switch the machine off and on after executing this SP.
Remote ROM Update
When set to "1" allows reception of firmware data via the local port (IEEE 1284) during a
remote ROM update. This setting is reset to zero after the machine is cycled off and on. Allows
the technician to upgrade the firmware using a parallel cable
5856
[0 to 1/1]
0: Not allowed
1: Allowed
5857
Save Debug Log
On/Off (1:ON 0:OFF)
Switches on the debug log feature. The debug log cannot be captured until this feature is
switched on.
1
[0 to 1/1]
0: OFF
1: ON
Target (2: HDD 3: SD Card)
Selects the destination where the debugging information generated by the event selected by
SP5858 will be stored if an error is generated
2
[2 to 3 /1]
2: HDD
3: SD Card
Group 5000
4
369