Ricoh V-C3 D081 Field Service Manual page 834

Table of Contents

Advertisement

4. Appendix: Service Program Mode Tables
3 Density Adj Mode
4
4 ACC Before ProCon
5 DnstyAdjTimes
6 DevGamma(Env Corrct)
7 DevGamma(Time Corrct)
3511
Poten Tbl:Disp
256
Sets the execution timing of toner density adjustment with the
automatic process control self-check.
[0 to 3/1]
0: Do not execute,
1: 1st Power On,
2: 1st Power On & Job End
Determines whether process control is executed before a
gradation test pattern is printed using the operation panel
with: [User Tools]> Maintenance> Auto Color Calibration
[0 to 3/2/1]
0:Do not execute
1:Execute Potential Control
2:Execute Potential Control and Toner Density Adjustment
Sets the upper limit of the loop wherein density is adjusted
during process control. Default: 5
Switches correction of the development gamma adjustment
with the readings of the temperature/humidity sensor off and
on. Touch either the "OFF" or "ON" button to toggle the
setting.
Switches the timing of the development gamma adjustment
during process control off and on. Touch either the "OFF" or
"ON" button to toggle the setting.