4. Appendix: Service Program Mode Tables
2 Tnr Mtr On Time
290
Stop Time Reverse Ctrl
6
The K drum motor, YMC drum motor, ITB motor, and PTR motor can be set to reverse slightly
immediately after they stop. This removes dust from the edges of the cleaning blades. These SP
codes:
• Switch this feature on/off (Default: OFF)
• Set the absolute intervals (distance) for execution of stop/reverse timing
4
• Set the intervals (distance) for execution of stop/reverse timing during long print jobs.
1 Set Rev Execute:K
2 Set Rev Execute:YCM
3 Set Rev Execute:ImgTrans
4 Set Rev Execute:PaperTrans
5 Set Rev Execute Interval
6 Assign Execution
7 Set Execute Interval
8 Op Time Setting:Bk
9 Op Time Setting:YCM
238
Sets the amount of time the motor remains on.
[1 to 10/1 sec.]
These SP codes switch on/off the stop/reverse
feature for the K PCU drum motor, YMC PCU drum
motor, ITB motor, and PTR motor.
Default: Off
Sets the distance interval between motor stop/
reverse executions.
[1 to 500/ 1 m] Default: 30 m
Switches on the time interval that controls motor
reverse executions during continuous print jobs.
Sets the distance interval between motor reverse
executions during continuous print jobs.
[1 to 500/ 1 m] Default: 250 m
Sets the length of time for the K PCU drum motor
to reverse.
[2 to 500/30/2 msec]
Sets the length of time for the YMC PCU drum
motors to reverse.
[2 to 500/30/2 msec]

Advertisement