2. Attach the seal to the guide sheet provided. This reminds you which SP codes must be set for the PCU
later.
3. Remove the screw and attach the plate to the correct position for the PCU to be replaced. This
adjustment prevents the PCU from being installed in the wrong position.
4. Install the new PCU in the machine.
5. Execute the SP codes listed on the guide sheet.
• Enter the values for the SP codes before you add developer.
6. Enter the values written on the seal for each SP code