Ricoh V-C3 D081 Field Service Manual page 405

Table of Contents

Advertisement

5. At the back of the fusing unit, loosen the screw of the lock/release lever [A]. (Do not remove the
screw.)
6. Rotate the lever [B] away from the pin, then tighten the screw with the lever in the open position.
(Tightening the screw keeps the lever at the open position so that the fusing unit can be reinstalled
easily.)
7. Loosen both screws [A] ( x2). (These screws cannot be removed.)
8. Press down both levers [B] (front and back) to unlock (to release the pins [C] at front and back).
9. Lift the fusing unit out of the drawer.
10. Set the fusing unit on a clean surface.
Reinstallation
Fusing Unit
4