Chapter 7 - Configuring the Gateway
System Specifications
Minimum Requirements
7-4
The GW-25/GW-45 conforms to the following standards:
Audio standards: G.711a, G.711u, G.722, G.723 (H.323 only), G.728,
•
SIREN7, SIREN14
•
Video standards: H.261, H.263, H.264
Video resolution: CIF, QCIF
•
Communication Standards: H.320, H.323
•
Call setup standards: H.245 (H.323) and H.221 (H.320)
•
Content standard: H.239
•
Data Rates: Up to E1 (1920 Kbps)
•
MGC or Gateway
•
H.323 Card (2 Cards required for IP to IP Gateway communications)
•
•
ISDN Net Card (Requires minimum 1 PRI with a range of DID numbers)
•
MUX Card
Audio Card
•
Video Card (Optional - for Transcoded calls)
•
Software Requirements
MGC Version 4.00.XXX or above
•
MGC Manager Version 4.00.XX or above
•
Network Requirements
ISDN PRI line for H.320 Participants
•
ISDN PRI line should have a range of 10 - 20 DID numbers available for
•
Gateway communications
•
Switched Ethernet connection to each H.323 card in the MCU
•
10/Half Ethernet connection for management of the MGC/Gateway
Static IP address for the MGC/Gateway management port
•