Chapter 5 - MCU System Management
5-64
Section PERFORMANCE_MONITORING
AUTO_PERFORMANCE_MONITORING=NO
•
Enable the Automatic Performance Monitoring. Once the thresholds are
for the various error conditions are exceeded, the system issues a fault
message (in the Faults dialog box) and the MCU status changes from
Normal to Minor). For more information see "Appendix C: Performance
Monitoring NET-T1/Net-E1" on page C-1.
PERFORMANCE_MONITORING_TIMEOUT=60
•
The performance monitoring time-out.
Section UTIL PASSWORD
PSOS_NET_UTIL = YES
•
PSOS (OS) Utilities Tasks (Shell, FTP & Telnet), Can be used in case
customer prefers to disable FTP & Telnet due to security issues.
(Applicable only for pSos and not for XPEK.
FTP_LOGIN = NO
•
When set to YES, enables password verification for FTP Sessions,
otherwise, a password is not required.
•
IPTERMINAL_LOGIN = NO
Enable Password for IP Terminal. In the IP Terminal type login then
password (in the same command line).
ALLOW_ORDINARY_OPERATOR_TO_CHANGE_ITS_OWN_
•
PASSWORD = YES
When set to YES enables the Operator with "ordinary permission" to
change his own password. The Operator with "superuser permission" can
change all operator's passwords.
When the flag is set to NO, no operator will be able to change passwords,
only delete and create new ones.
Section XPEK
•
CREATE_DUMP_FILE_WHEN_EXCEPT = YES
Used for debugging purposes – start the debugger in case of exception.
SILENT_MODE = YES
•
Set this flag to YES (default) to increase MGC unit security. As a
hacking preventive measure, the MCU is set to Silent Mode in order to
Need help?
Do you have a question about the MGC Administrator and is the answer not in the manual?