Chapter 5 - MCU System Management
5-116
The files are created sequentially, cyclically, when the 100
the first file and so on. Recommended mode is NO (manual card monitor).
The file names are generated automatically, containing the following
components:
Text: vp_logger
•
Board ID number
•
Unit ID number
•
A serial number between 0 and 99, ascending sequentially
•
For example, a file could be named: vp_logger 4 2 03 where 4 is the Board
ID number, 2 is the Unit ID number and 03 is the serial number between 0
and 99.
Manual creation of the Video+ logger files:
In the IP Terminal window, type the command:
vp_logger <board_id> <unit_id>
Where <board_id> is the Video+ board slot number (in the MGC 25, the
"logical" slot number as appears in the MGC Manager) and <unit_id> is the
mapped unit ID (0 for Card Manager).
For example, type vp_logger 5 0
The file is stored in the MCU under the directory 7.256\mcu\vp_log\. This
folder is automatically created by the system if it does not exist on the MCU.
th
file overwrites