Assigning the T1-CAS Network Service to the Net-2/Net-4/Net-8

Card

In order to connect the MCU to the network switch, you need to assign the
T1-CAS Network Service to the appropriate span of the Net-2/Net-4/Net-8
Network Interface module.
It is not possible to mix an ISDN Network Service and a T1-CAS Network Service
on the same Net-2/Net-4/Net-8 Network Interface module. Therefore, the Net-2/
Net-4/Net-8 card can only be used with either ISDN or T1-CAS Network Service.
Before you assign the T1-CAS Network Service to the card, you must set the
following 'system.cfg' flag: in the NET8_PARAMETERS section, set
NET8_DEFAULT_TYPE = to T1-CAS.
In addition, you may define which span in the network interface card is used
as the primary clock and which one as the backup clock in order to
synchronize with the network clock.
To assign the T1-CAS Network Service to the Net-2/Net-4/Net-8 Network
Interface module:
1.
In the Browser pane, right-click the slot containing the Net-2/4/8 card,
and then click Properties. Alternatively, double-click the slot containing
the card.