THRESHOLD_LATENCY=300
•
Determines the maximum time it takes a packet to travel from one end to
another. The threshold is defined in fractions of 1000, therefore, a
threshold of 100 defines 10%. Entering zero disables the flag.
THRESHOLD_FRAME_RATE=0
•
Determines the acceptable deviation, in percentage, from the expected
channel frame rate. The threshold is defined in fractions of 1000,
therefore, a threshold of 100 defines 10%. Entering zero disables the
flag.
•
DEFENCE_PERCENT = 95
Indicates to end point the percentage to send us of the actual bit rate to
protect the MCU from bursty end point. 100% means that we are not
protecting MGC from bursty end point. The value can be any value
100% or less. Usually 95% is sufficient.
ACTIVE_PROTECTION_NUMBERING=YES
•
YES - Ignores duplicate messages
NO - Does not ignores duplicate messages
Section IP LOAD FLAGS
•
SIP_REGISTER_LOAD = 80
The amount of resources the process consumes. Measured in 0.1%.
Possible values are 1 to 1000.
Section IP CARD MONITORING
IP_MONITORING_SHOW_FAULTY_MARK = YES
•
YES - Show participant monitoring section with a red fault ('!')
indication in MGC manager
NO - don't show any participant indication
Section H323 GK FLAGS
PREFIX_TYPE_IS_H323ID = NO
•
Enables the Prefix type (for most of GK, it is E.164).When using ECS
Gate Keepers need to be set to YES
YES – H320_GW
NO – H323_GW
MGC Administrator's Guide