Appendix A: Faults
A-12
Table A-6: General Fault Descriptions (Continued)
Code
_
_
_
NO
AUDIO
MESSAGE
CONFIGURATION
_
_
NO
CLOCK
SOURCE
_
_
_
NO
MUSIC
IN
CONFIGURATION
_
PASSWORDS
CONFLICT
_
_
PLEASE
SEE
pscnflct_log_
_
_
FILE
FOR
DETAILS
_
_
POWER
SUPPLY
FAILURE
_
_
_
RESET
MCU
BY
OPERATOR
_
_
SINGLE
CLOCK
SOURCE
Level
Description
_
major
Occurs when the MESSAGE flag in the
IN
system.cfg file, ATTENDED section is
configured to YES, but there is no
suitable hardware in the system.
major
This error usually follows a red, blue or
yellow alarm. If the MCU fails to
identify the PRI line it is unable to
synchronize itself by the PBX.
major
Occurs when the MUSIC flag in the
system.cfg file, ATTENDED section is
configured to YES, but there is no
suitable hardware in the system.
__
startup
The password assigned to a
conference or reservation loaded from
a previous version is not valid in the
current version. For details see the
pscnflct.log file in the MCU root
directory.
Applicable to MGC-25 only.
The power supply failed.
minor
The MCU was reset by the MGC
Manager from the Reset MCU sub-
menu.
minor
Only one span was able to synchronize
itself with the PBX. The system will
continue to function normally but there
will be no backup clock source. If there
are more than one net (T1 or E1) cards
connected to the PBX, this may
indicate a problem with the connection
to the PBX.