9.3.2.13 External Interrupt Configuration Register

IntConfig is the External Interrupt Configuration Register. The active bits used in this reg-
ister are Read/Write.
This register configures the individual external interrupts to be either edge-sensitive or
level-sensitive and either active HIGH or active LOW. When reset, all bits are cleared and
configure the external interrupts to be active LOW-level sensitive. The corresponding
edge-trigger interrupt should be cleared before enabling the edge-trigger interrupt to
clear a false interrupt.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR
BITS FIELD NAME
31:16
15:14
13:12
11:10
9:8
7:6
9-18

Table 9-30. IntConfig Register

31
30
29
28
27
0
0
0
0
0
R
R
R
R
R
15
14
13
12
11
///
INT6
0
0
0
0
0
R
R
RW
RW
RW

Table 9-31. IntConfig Register Definitions

///
Reserved Writing to these bits has no effect. Reading returns 0.
///
Reserved Read as 0, do not modify.
Configures External Interrupt INT6
00 = Configures INT6 to be a LOW-level trigger.
INT6
01 = Configures INT6 to be a HIGH-level trigger.
10 = Configures INT6 to be a falling-edge trigger.
11 = Configures INT6 to be a rising-edge trigger.
Configures External Interrupt INT5
00 = Configures INT5 to be a LOW-level trigger.
INT5
01 = Configures INT5 to be a HIGH-level trigger.
10 = Configures INT5 to be a falling-edge trigger.
11 = Configures INT5 to be a rising-edge trigger.
Configures External Interrupt INT4
00 = Configures INT4 to be a LOW-level trigger.
INT4
01 = Configures INT4 to be a HIGH-level trigger.
10 = Configures INT4 to be a falling-edge trigger.
11 = Configures INT4 to be a rising-edge trigger.
Configures External Interrupt INT3
00 = Configures INT3 to be a LOW-level trigger.
INT3
01 = Configures INT3 to be a HIGH-level trigger.
10 = Configures INT3 to be a falling-edge trigger.
11 = Configures INT3 to be a rising-edge trigger.
LH75400/01/10/11 (Preliminary) User's Guide
26
25
24
23
///
0
0
0
0
R
R
R
R
10
9
8
7
INT5
INT4
INT3
0
0
0
1
RW
RW
RW
RW
0xFFFE2000 + 0x80
DESCRIPTION
7/15/03
22
21
20
19
18
0
0
0
0
0
R
R
R
R
R
6
5
4
3
2
INT2
INT1
0
0
0
0
0
RW
RW
RW
RW
RW
17
16
0
0
R
R
1
0
INT0
0
0
RW
RW