Install the ferrite core (provided with the unit) about two inches
from the line cord plug.
Figure 12-18 Installing the Ferrite Core on the AP(A)-R( )/AP(R)-R( )
4.
Connect the line cord to the unit, limiting the cable length from
the AP(A)/AP(R)-R( ) Unit to the single line telephone to a
maximum of 50 feet.
When only installing the AP(R)-R( ) Unit, plug the AC Adapter (AC-2R/
AC-3R Unit) power cord into the indicated AP(R)-R( ) Unit receptacle
and connect it to a power source. Refer to
Adapter to an Installed Adapter on page
5.
Replace the base plate (or wall mount unit) and attach the line
cord. Refer to
System on page

CT(A)-R( ) Unit (Computer Telephony Adapter)

The Computer Telephony Adapter, CT(A)-R( ) Unit allows a multiline terminal to
be connected to a PC. The PC can perform all multiline terminal functions
using a TAPI-compatible application software (Microsoft Telephony Application
Programming Interface).
The multiline terminal must be located within five feet (1.5 m) of the PC. An AC-
2R/AC-3R Unit is necessary.
AP(A)-R( ) Unit
or
AP(R)-R( )
Unit
Section 3 Connecting a Multiline Terminal to the
11-8.

Figure 12-19 CT(A)-R( ) Unit

Installing D
UNIVERGE SV8100/SV8300
Unit
Figure 12-5 Connecting the AC
12-4.
term
Series i Optional Equipment

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents