External Paging; External Page; Installing An External - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue No. 1.5
E
S
5
XTERNAL
ECTION
5.1
5.2
10 - 14
P
AGING

External Page

Two external page zone/door box circuits are provided by each PGD(2)-U( )
ADP installed. Each Door Box/external page circuit provides a dry relay contact.
The CD-CP00-AU also provides a connection for external paging and a relay.
The external page on the CD-CP00-AU is speaker number 9 – the relay is
number 0. The external page speakers provided by the PGD(2)-U( ) ADPs are
1-8 – the relays on the PGD(2)-U( ) ADPs are numbered 1-8.
The PGD(2)-U( ) ADP can be used for talkback with External Page, as can a
CO trunk port with the proper external page equipment (ex: Valcom) – set
Program 31-06-03 to 0 for talkback. However, the external page circuit on the
CD-CP00-AU cannot be used for talkback.
A PGD(2)-U( ) ADP circuit used for External Paging
cannot also be used for an analog Door Box.
Installing an External Page System
1.
Connecting to the CD-CP00-AU:
Connect an RCA line from the CN8 or CN9 connector on the
CD-CP00-AU to the appropriate location on the extension cross-connect
block.
2.
Connect the two-conductor station cable from the cross-connect block to
the external relay/external page.
3.
Install bridging clips as required.
OR
1.
Connecting to the PGD(2)-U( ) ADP:
Make sure the jumper in the PGD(2)-U( ) ADP for the channel is set
correctly. (Refer to
page
10-4).
2.
If a line cord was not previously connected to the PGD(2)-U( ) ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U( ) ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a modular
jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U( ) ADP.
Figure 10-4 PGD(2)-U( ) ADP Jumper Settings on
Installing SV8100/SV8300 Optional Equipment
UNIVERGE SV8100/SV8300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents