UNIVERGE SV8100/SV8300
6.3
System Hardware Manual
A dedicated outlet, separately fused and grounded for each
chassis should be installed.
6.2.2

Power Supply Consumption

Chassis
Basic Chassis – CD-CP00-AU/EU/OT/US
Chassis
Basic Chassis + Expansion Chassis
Basic Chassis + 2 Expansion Chassis
Basic Chassis + 3 Expansion Chassis

Environmental Conditions

6.3.1

Temperature and Humidity

Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~
60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50-AU/EU/OT/US,
CD-8DLCA, CD-16DLCA, PZ-8DLCB
Operating Temperature: +32°F ~ +104
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~
60°C)
Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTB,
PZ-4COTG, CD-PRTA
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 20 ~ 90% RH
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).

Table 2-17 Power Consumption

Maximum
RMS
Current
1.15 A
2.3 A
3.45 A
4.5 A
Issue No. 1.5
Watts Used
Watts Used
(Idle)
(Maximum)
180
120
240
360
360
540
480
720
o
o
o
F (0
C ~ 40
C)