Night Mode Selector Switch

The Night Mode Switch relay closes when the system detects either an open or
closure on the MISC block NIGHT SW terminals. Maximum 48v DC is output to
the switch when open, and 7mA DC when shorted.

Connecting a Night Mode Selector Switch

1.
Connect an RJ-61 modular line cord from the CN17 connector on the
CD-CP00-AU to the appropriate location on the extension cross-connect
block.
2.
Connect the two-conductor station cable from the cross-connect block to
the night switch mechanism output leads.
3.
Install bridging clips as required.

Figure 10-17 PGD(2)-U( ) ADP Connections