Installation; Figure 6-27 Pri Layout For Nt-1 Network - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue No. 1.5
6 - 78
Speech and 3.1 KHz audio
When installed, CD-PRTA uses the first block of 30 consecutive trunk
ports. For example, if a COIU blade is installed for trunks 1~8, the
CD-PRTA automatically uses trunks 9~38. If the COIU blades are
installed for trunks 1~8 and 17~24, CD-PRTA uses trunks 25~55. The
CD-PRTA cannot use trunks 9~16 (even if available) since they are
not part of a consecutive block of 30 trunks. Each CD-PRTA requires
30 ports in the system, even if not all the ports are used, otherwise the
blade does not function.
The CD-PRTA requires one universal slot and provides:
2M Function
Refer to the following table for maximum upgrade capacities of the
CD-PRTA
blade:
Table 2-4 SV8100 Maximum System Capacities – Blades on
page 2-7
5.6.2

Installation

To install the CD-PRTA:
1.
Plug the CD-PRTA into any universal slot on the chassis.
2.
Connect the cable from the NT1 Network Termination cable to
the CN2 connector on the CD-PRTA.
NT-1 Network on page 6-78

Figure 6-27 PRI Layout for NT-1 Network

UNIVERGE SV8100/SV8300
With normal operation, LED 1 flashes green.
is a cabling diagram.
Installing the SV8100/SV8300 Blades
Figure 6-27 PRI Layout for